Technical Data Measure Head
Sensor head: Statox 505 (Type 5375)
Display: 8 – digits, 14 segments
Output: 4-20 mA, max. load 700 Ohm
Service mode: 0 or 2 mA
System fail: 0 or 2 mA
Overrange: 22 mA
Protection class: IP65
Approval: II 2 G EEx ib IIC T4
Dimensions (WxHxD): 200 x 120 x 90 mm
Pressure: 900 – 1100 hPa
Operation- and storage temperature: -30 – +60°C
Power supply: 12 – 28 V DC max. 22 mA
Weight: 0,75 kg
Housing: Chromium plated ABS, stainless steel,  mounting plate stainless steel
Operation voltage Ui: max. 28 VDC
Operation current: max. 93 mA
Internal capacity Ci: neglectible
Internal inductivity Li: neglectible
EMC: EN 50270
Functional safety: SIL2 according to EN 50402
Technical Data Sensors
Sensors Measuring range Operating temperature Humidity
Ammonia NH3  0 – 150 ppm -20 – +50°C 15 – 95 %
Hydrogen cyanide HCN  0 – 20 / 100 ppm -20 – +50°C 20 – 95 %
Chlorine Cl2  0 – 5 ppm -20 – +50°C 20 – 95 %
Carbon monoxide CO  0 – 300 ppm -20 – +50°C 20 – 90 %
Hydrogen fluoride HF  0 – 10 ppm -20 – +50°C 20 – 90 %
Oxygen O2  0 – 35 % -20 – +50°C 20 – 95 %
Sulphur dioxide H2S  0 – 20 / 100 ppm -20 – +50°C 20 – 95 %
Ozone O3  0 – 1 ppm  20 – + 50°C 20 – 90 %
Nitrogen NO2  0 – 5 ppm -20 – +50°C 20 – 95 %
Hydrogen H2  0 – 300 ppm -20 – +50°C 20 – 90 %
Hydrogen chloride HCl  0 – 50 ppm -20 – +50°C 20 – 95 %
Arsine AsH3  0 – 500 ppb -20 – +50°C 20 – 80 %
Phosphine PH3  0 – 1 ppm -20 – +50°C 20 – 80 %
Hydrazine N2H4  0 – 1 ppm -20 – +50°C 20 – 95 %
Phosgene COCl2  0 – 0,5 / 1 / 100 ppm -20 – +50°C 20 – 95 %
Chlorine dioxide ClO2  0 – 1 ppm -20 – +50°C 20 – 95 %
Sulphur dioxide SO2  0 – 5 ppm -20 – +50°C 20 – 95 %

Manuals

Statox 505

Brochures

Statox 505

Compatible Control Module

Statox 503