Statox 4120 – Gas monitor with self test

This product has been further developed and is unfortunately no longer available. You can find the successor here: Statox 560

However, spare parts are still available.

Technical Data – Measure Head
Product name: Statox 4120
Protection class: IP53
Certificate: E Ex ib IIC T6
Dimensions (HxWxD): 180 x 180 x 300 mm
Weight: 1,9 kg
Technical Data Sensors
Sensor Measure range  Ambient temperature  rel. Humidity
 Carbon monoxide CO:  0 – 150 ppm  -20 – +40°C  20 – 90 %
 Chlorine Cl2:  0 – 10 ppm  -20 – +40°C  30 – 80 %
 Chlorine dioxide:  0 – 0,5 ppm  -20 – +40°C  20 – 95 %
 Hydrogen cyanide HCN:  0 – 50 ppm  -20 – +40°C  20 – 90 %
 Hydrogen sulfide H2S:  0 – 100 ppm  -20 – +40°C  20 – 90 %
 Phosgene COCl2:  0 – 1,5 / 15 ppm  -20 – +40°C  20 – 90 %
 Nitrogen dioxide NO2:  0 – 15 ppm  -20 – +40°C  20 – 90 %
 Sulfur dioxide SO2:  0 – 5 ppm  -20 – +40°C  20 – 90 %
Technical Data Control Module
 Recorder output:  0 – 1 V, 4 – 20 mA
 Alarms:  dual-level, user adjustable
 Relays:  alarm 1, alarm 2, system fault, max. 24 V/100 mA
 LED:  alarm 1, alarm 2, system run, system fault
 Data display:  LED bar graph
Technical Data Central Unit
 ½ l9″-rack maximum of 4 plug-in control panels  Dimensions: 180 x 270 x 420 mm (HxWxD)
 19″-rack maximum of 9 plug-in control panels  Dimensions: 180 x 485 x 420 mm (HxWxD)
 Certificate:  [E Ex ib] IIC
Technical Data Diagnostic Unit
 Certificate  E Ex ib IIC T6
 Dimensions  50 x 160 x 190 mm (HxWxD)
 Weight  330 g
Statox 4120 Messkopf mit Dianosegerät

Manuals

Statox 4120

Brochures

Statox 4120