Honeywell Micro 5 – Measures up to 5 gases simultaneously
The Micro 5 multi-gas detector monitors up to 5 gases simultaneously. A wide range of options allows the user to customise the device exactly to their needs.
In addition to the catalytic sensor for measuring combustible gases, the gas detector offers a wide range of electrochemical sensors for detecting toxic gases and oxygen, as well as an IR sensor for measuring carbon dioxide (%CO2) and PID sensor technology for measuring volatile organic compounds (VOCs).
The sampling pump is very powerful, allowing sample gas to be drawn in from a distance of up to 20 metres. In this way, endangered areas can be measured before being entered.
Micro 5 multi-gas detectors are compatible with the MicroDock II automatic test and calibration station.
Measurement with PID
Micro 5 multi-gas detectors can measure volatile organic compounds (VOCs) in work areas with a photoionisation detector (PID). VOCs are, for example, organic solvents, paint thinners, benzene, butadiene, hexane, toluene and fuels such as petrol, diesel, heating oil, paraffin and jet fuel.
Quick navigation:
Technical data | Downloads
Technical data
Application | Personal protection | ||||||
Gas type | Measurement range | Measurement principle | Resolution | Fine resolution | Micro5 | Micro5 IR | Micro5 PID |
Combustible gases | 0 – 100 % LEL, 0 – 5 % CH4 | Catalytic | 1 % LEL, 0.1 % vol | – | yes | yes | yes |
Oxygen | 0 – 30 % vol. | electrochemical | 0.10 % | – | yes | yes | – |
Carbon monoxide | 0 – 999 ppm | electrochemical | 1.0 ppm | – | yes | yes | yes |
Hydrogen sulphide | 0 – 500 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | yes | yes |
Twin CO / H2S | 0 – 500 ppm | electrochemical | 1.0 ppm | – | yes | yes | yes |
Sulphur dioxide | 0 – 500 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | yes | yes |
Chlorine | 0 – 50 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | – | – |
Nitrogen dioxide | 0 – 99 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | – | yes |
Carbon dioxide | 0 – 50,000 ppm | infrared | 50 ppm | – | – | yes | – |
Ammonia | 0 – 100 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | yes | yes |
Hydrogen cyanide | 0 – 30 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | – | yes |
Phosphine | 0 – 5 ppm | electrochemical | 1.0 ppm | 0.1 ppm | yes | – | yes |
Chlorine dioxide | 0 – 1 ppm | electrochemical | 1.0 ppm | 0.01 ppm | yes | – | yes |
Ozone | 0 – 1 ppm | electrochemical | 1.0 ppm | 0.01 ppm | yes | yes | yes |
VOC | 0 – 1000 ppm | Photoionisation | 1.0 ppm | – | – | – | yes |
Operation | Alphanumeric backlit display, menu-guided operation via buttons | ||||||
Configuration | The device is delivered pre-configured. The user can modify the factory settings. | ||||||
Memory | Continuous data storage for months | ||||||
Housing | Highly durable plastic. Antistatic according to EN 50014 | ||||||
Dimensions | 145 * 74 * 38 mm | ||||||
Weight | 370 g | ||||||
Protection class | IP 65 / 66 | ||||||
Operating temperature | -20 – +50°C PID Version -10 – +40°C | ||||||
Alarms | Vibration, visual and audible (95 dB). Alerts include pre- and main alarms, short- and long-term value exceedance, overrange | ||||||
Self-test | Sensors, electronics, all alarms, battery | ||||||
Power supply | Li-Polymer battery. Capacity 20 h Micro5 or 15 h Micro5 IR and Micro5 PID | ||||||
Pump | Integrated electric pump module. Suction from max. 20 m | ||||||
Certifications | Micro5, Micro5 PID: Ex II 1 G, EEx ia IIC T4, Micro5 IR: Ex II G, EEx d ia IIC T4 | ||||||
Delivery contents | User manual CD and printed, stainless steel clip, battery, charging station, gas adapter | ||||||
Accessories | See below | ||||||
Warranty | 24 months, except sensors for chlorine, ammonia, chlorine dioxide and PID (12 months) |